Customized Hybrid Fiber and Power Cable, Indoor, Riser (OFNR)/Plenum (OFNP), 2-12 Fibers, LC/SC/Unterminated, 2 Conductors
Hybrid cables have both fibre and copper conductors under the same cable jacket to deliver data and power to the very edge of the enterprise network. By integrating fibre and copper in one cable, the cables eliminate the need to install separate fibre and power cables. This saves installation time, labour costs and duct or tray space. And hybrid cables simplify the process of supplying data and power to remote devices, even in locations where a power outlet is unavailable. Additionally, the cables achieve ultimate flexibility by bringing together the future-ready bandwidth capabilities of optical fibre and the powering capabilities of copper.
Product Highlights
2-in-1 Hybrid Cable Design, One Cable Meets Signal and Power Needs
>99.95% Oxygen-Free Copper Conductors with Stable Transmission Performance
Available in 2, 4, 8 and 12 Fiber Counts
Available in 12, 14, 16, 17 and 18AWG Conductor Gauges
Available in Tight-Buffered and Loose-Tube Cable Types
Streamlining Infrastructure onto a Single Cable Allows for Overcoming Space Constraints
Used for Indoor Communication or Industrial Pathways Requiring Combined Data and Power
Specifications
| Connector Type | LC/SC/Unterminated | Polish Type | UPC/APC |
| Fiber Count | 2/4/8/12 Fibers | Fiber Grade | OS2: G.657.A2 OM3/OM4: Bend Insensitive Fiber |
| Fiber Mode | OS2/OM3/OM4 | Wavelength | OS2: 1310/1550nm OM3/OM4: 850/1300nm |
| Conductor Count | 2 Conductors | Conductor Gauge | 12/14/16/17/18AWG |
| Conductor Material | >99.95% Oxygen-Free Copper | Conductor Type | Stranded |
| Flame Rating (Trunk) | Riser (OFNR)/Plenum (OFNP) | Breakout Length | 0.3/0.5m Equal Breakout (Default) |
| Construction Type | Non-Armored | Cable Type | Tight-Buffered/Loose-Tube |
| Trunk Outside Diameter (OD) | 7.0-15.5mm | Breakout Outside Diametre (OD) | 2.0mm (Fiber) |
| Min. Bend Radius (Optical Fiber) | 7.5mm | Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Crush Resistance | 500N/100mm (Short Term) | Tensile Load | 80/100N (Long/Short Term) |
| Insertion Loss | < 0.3 dB | Return Loss | OS2: UPC≥50dB, APC≥60dB OM3/OM4: UPC≥30dB |
| Attenuation | OS2: 0.4dB/km at 1310nm, ≤0.3dB/km at 1550nm OM3/OM4: ≤3.5dB/km at 850nm, ≤1.5dB/km at 1300nm | Voltage | 300V AC |
| Operating Temperature | -5 to 60°C (23 to 140℉) | Storage Temperature | -10 to 70°C (14 to 158℉) |
Connectivity Solutions

Features
2-in-1 Hybrid Cable Design, Fiber and Power
By integrating fibre and copper in one cable, a single cable transmits high-speed data and stable power simultaneously, replacing traditional dual-cable deployment to simplify wiring.

Custom Trunk Cable Jacket
A cable jacket is a shield that protects and ensures the longevity and reliability of the cable within. The differences in cable jacket types determine their suitability for different scenarios.

Integrated Dual Transmission Performance
The hybrid cables achieve ultimate flexibility by bringing together the future-ready bandwidth capabilities of optical fibre and the powering capabilities of copper. This saves pathway space, labour costs and speeds up deployment.


FAQ
1. What is a customized hybrid fiber and power cable?
A customized hybrid fiber and power cable combines optical fibers and copper power conductors under one cable jacket. It allows remote devices to receive both data and power through a single cable, helping network integrators simplify installation and reduce the need for separate fiber and power cables.
2. What applications are these hybrid cables designed for?
These cables are designed for indoor enterprise networks, data communication systems, security and surveillance deployments, wireless infrastructure, remote access points, and other projects where a device requires both fiber connectivity and local power. Contact us with your project requirements for a suitable cable design.
3. What fiber counts are available?
We can provide configurations from 2 to 12 optical fibers. The final fiber count can be selected according to your network architecture, equipment interfaces, link requirements, and bill of materials (BOM).
4. Which fiber connectors can be supplied?
The cable can be supplied with LC connectors, SC connectors, or unterminated fiber ends. Connector type, polish, fiber mode, boot color, polarity, and breakout design can be specified in your RFQ or technical drawing.
5. Can I order the cable with unterminated fiber ends?
Yes. Unterminated cable assemblies are available for field termination, splicing, or integration with customer-specified termination systems. This option can be useful for system integrators and project contractors that complete installation on site.
6. How many copper conductors does the cable include?
The standard product configuration includes 2 copper conductors for power delivery. Conductor size, insulation, voltage requirements, current requirements, jacket construction, and other electrical specifications should be confirmed before quotation and production.
7. Can the copper conductor specifications be customized?
Yes. For OEM and project-based orders, copper conductor size, conductor material, insulation type, color coding, and electrical requirements can be reviewed according to your application. Please provide the target voltage, current, operating environment, and installation method for an accurate engineering assessment.
8. What does the Riser (OFNR) rating mean?
The Riser (OFNR) version is intended for vertical runs between building floors or through riser spaces where the applicable project code permits this cable type. The required jacket rating should always be selected according to local regulations, building codes, and the project specification.
9. What does the Plenum (OFNP) rating mean?
The Plenum (OFNP) version is designed for use in plenum spaces where stricter fire and smoke performance requirements apply. Project engineers and contractors should confirm whether OFNP is required by the building code before placing a bulk order.
10. Can I choose between OFNR and OFNP cable jackets?
Yes. OFNR and OFNP jacket options can be evaluated according to the installation area and compliance requirements. When sending an RFQ, please specify the building zone, cable pathway, applicable standard, and required jacket rating.
11. What are the main benefits of using a hybrid fiber and power cable?
A hybrid cable carries data and power in one jacket, which can reduce the number of cables requiring installation. This may help save installation time, labor costs, conduit or tray space, and project coordination effort compared with deploying separate fiber and power cables.
12. Can these cables supply power where no power outlet is available?
They can help deliver power to remote devices through the integrated copper conductors, including locations where a nearby power outlet is unavailable. The actual power-delivery capability depends on the conductor size, cable length, voltage, current, temperature, and device load. These parameters must be confirmed during project design.
13. Are these cables suitable for remote network devices?
Yes. They are suitable for remote devices that require both optical data connectivity and electrical power. Typical examples may include remote access equipment, surveillance devices, wireless infrastructure, and other edge-network equipment, subject to the device interface and power requirements.
14. Can you manufacture cables according to our technical drawing?
Yes. We support custom cable manufacturing based on customer drawings, cable schedules, BOMs, samples, or written specifications. Our engineering team can review fiber count, connector configuration, conductor requirements, jacket rating, cable length, labeling, and packaging before issuing a quotation.
15. Do you support OEM and ODM orders?
Yes. OEM and ODM services are available for qualified business customers. Custom options may include cable construction, fiber and copper specifications, connectorization, jacket marking, labels, packaging, and project-specific documentation.
16. What is the minimum order quantity (MOQ)?
MOQ depends on the cable construction, fiber count, connector configuration, custom materials, packaging, and production requirements. Please send your target quantity and specifications so we can confirm the applicable MOQ for your project or bulk order.
17. Can I request samples before placing a bulk order?
Yes. Samples can be arranged for product evaluation, compatibility testing, installation trials, and engineering approval. Sample availability, sample charges, and delivery time depend on whether the requested configuration is standard or fully customized.
18. What information is needed for an accurate quotation?
For an accurate RFQ response, please provide the required fiber type and count, cable length, LC/SC/unterminated configuration, connector polarity if applicable, copper conductor specifications, OFNR or OFNP rating, quantity, packaging requirements, destination, and target delivery schedule.
19. What is the production lead time for a custom order?
Lead time depends on the cable design, raw material availability, connectorization, testing requirements, order quantity, and packaging. After reviewing your specifications, we can provide a project-specific production schedule and shipping plan.
20. Can you provide technical support and project documentation?
Yes. We can support product selection, cable configuration review, RFQ preparation, sample evaluation, and project-based sourcing. Technical documents such as product specifications, cable drawings, test information, packing details, and other available documents can be discussed according to the project and customer requirements.
CONTACT US
Take advantage of our unrivaled knowledge and experience, we offer you the best customization service.
SEND US A MESSAGE
HOTLINE
+8613509645699
EMAIL
RECOMMENDED
They are all manufactured according to the strictest international standards. Our products have received favor from both domestic and foreign markets.
They are now widely exporting to 200 countries.