  • Product Details

Product Highlights

Helical Steel Armor Provides Additional Crush, Bending, Pulling, and Rodent Protection

Eliminate the Need for Conduits to Improve Design Flexibility and Lower Installed Costs

Pull-proof Jacket with Max. 225N Tensile Strength

G.657.A1 Bend-Insensitive Fiber & 10/5D (Dynamic/Static) Min. Bend Radius

Precision Zirconia Ferrule Connectors Ensure Low Loss

Used in Intrabuilding Backbone, Horizontal Installations, and Applications Requiring Extra Ruggedness


Specifications

Connector TypeLC to SCPolish TypeUPC to APC
Fiber ModeOS2 9/125μmFiber CountSimplex
Fiber GradeG.657.A1 (Compatible with G.652.D)Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mmFlame RatingRiser (OFCR-Optical Fiber Conductive Riser)
Construction TypeSingle Armored, Stainless Steel TubeTensile Strength120/225N (Long/Short Term)
Insertion Loss< 0.3 dBReturn Loss> 50 dB
Operating Temperature-20 to 70°C (-4 to 158°F)Storage Temperature-40 to 70°C (-40 to 158°F)


Connectivity Solutions

Tough Steel Tube Protects Network Connection Further

The stainless steel tube can provide great protection against optical fiber breakage and mechanical damage to create a reliable and high-performance fiber optic network.

Carrier-Grade Cable Ensures Transmission Quality

Superior cable assemblies ensure stable signal transmission and long-term reliability, minimizing failure rates.

Meet the Various Indoor Installation Needs

The exceptional durability of armored cables can be used to protect fibers and improve the reliability of the network for a variety of applications.




Armored OS2 CablesStandard OS2 Cables
Fiber CountSimplex / 1 FiberSimplex / 1 Fiber
Fiber GradeG.657.A1G.657.A1
JacketRiser (OFCR-Optical Fiber Conductive Riser)Riser (OFNR)
Cable Diameter3.0mm2.0mm
Insertion Loss< 0.3 dB< 0.3 dB
Min. Bend Radius
(Fiber Cable)
10/5D (Dynamic/Static)10/5D (Dynamic/Static)
Operating Temperature-25 to 70°C (-13 to 158℉)-20 to 70°C (-4 to 158℉)
ApplicationIndoor, Hazardous AreasIndoor, General Building


FAQ

Q1. What is an LC UPC to SC APC armored fiber patch cable?

An LC UPC to SC APC armored fiber patch cable is a factory-terminated single-fiber (simplex) jumper with an LC UPC connector (blue) on one end and an SC APC connector (green) on the other, built with a 3.0mm interlocked steel armor layer and OS2 single-mode fiber (9/125μm, G.652.D). Supplied directly by KEXINT — an armored fiber patch cable manufacturer and exporter — each unit is 100% factory-tested before shipment, making it a reliable choice for wholesale buyers and engineering contractors.


Q2. Why should I use a hybrid LC UPC to SC APC armored patch cord?

Modern active equipment — switches, routers and SFP+/QSFP optical transceivers — typically uses LC UPC interfaces, while PON networks (OLT, ONU, ODF panels) commonly use SC APC interfaces. This hybrid armored patch cord bridges both systems in a single cable: no adapter conversion, no field polishing, and no risk of damaging ferrule faces by directly mating UPC with APC. It is the practical, low-loss answer for mixed-infrastructure migration projects.


Q3. What optical performance does this OS2 single mode armored jumper deliver?

Typical factory-tested values: Insertion Loss ≤ 0.3 dB; Return Loss ≥ 50 dB on the LC UPC end and ≥ 60 dB on the SC APC end. The OS2 fiber supports 1310nm and 1550nm transmission with typical attenuation of ≤ 0.4 dB/km @ 1310nm and ≤ 0.3 dB/km @ 1550nm — performance suitable for data center, telecom and FTTH links. Batch test reports are supplied with every export order.


Q4. How does the built-in metal armor protect the fiber from damage?

The interlocked steel tape armor forms a rigid protective shell around the fiber that resists crushing, abrasion, cutting, pulling and rodent damage — the leading causes of fiber breaks and network outages in hazardous areas. Because the armor eliminates the need for conduit, installers get a smaller crush-resistant pathway, greater design flexibility and lower installed cost compared with conduit-based cabling.


Q5. Where are armored fiber patch cables typically installed?

Typical applications include data centers and server rooms, telecom rooms, FTTH/FTTB buildings, industrial plants and factory automation, mining and heavy industry, security/surveillance systems, and vertical riser shafts. Any route exposed to foot traffic, equipment movement or pulling during installation and maintenance benefits from armored construction.


Q6. What does Riser (OFCR) mean and why does it matter for building projects?

OFCR (Optical Fiber Communication Cable, Riser) is the UL 1666 flame rating for cables approved for vertical riser and building pathway installation between floors. Specifying a riser-rated armored patch cable helps your project pass fire-code inspection and is often a mandatory requirement in commercial and multi-tenant building tenders.


Q7. Can KEXINT provide custom lengths, connectors and OEM/ODM service?

Yes. KEXINT, as an experienced armored fiber patch cord factory, offers full customization: any cable length, connector combinations (LC/SC/FC/ST × UPC/APC), PVC or LSZH jacket, jacket colors, label and packaging design, and private-label/OEM production. Custom and standard configurations are both welcome — send your spec sheet for a factory-direct quotation.


Q8. What is the MOQ and lead time for wholesale or bulk orders?

MOQ is kept low to support first trial orders, and free samples are available for evaluation. Standard items ship fast from stock; custom orders have short lead times. Wholesale and bulk pricing is offered to distributors and system integrators, with secure packaging (bubble wrap + export cartons, or spools for long lengths) ready for international shipping.


Q9. What certifications and test documentation are provided?

Products are manufactured under an ISO 9001 quality system and available with UL (OFCR) compliance and RoHS compliance documentation. Each batch ships with insertion loss/return loss test reports and fiber type certification — full English documentation is provided to support your export and project-compliance requirements.


Q10. How do I choose a reliable armored fiber patch cable supplier?

Evaluate the supplier on four points: manufacturing qualification (ISO 9001, fire ratings), test data transparency, customization capability, and delivery lead time. KEXINT is a source factory that supports third-party factory audits and pre-shipment inspection, offers a product warranty, and provides responsive after-sales support — the combination buyers need for repeat, worry-free procurement.


Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

Recommended

Send your inquiry

CONTACT US

Take advantage of our unrivaled knowledge and experience, we offer you the best customization service.

SEND US A MESSAGE

The first thing we do is meeting with our clients and talk through their goals on a future project.
During this meeting, feel free to communicate your ideas and ask lots of questions.

RECOMMENDED

They are all manufactured according to the strictest international standards. Our products have received favor from both domestic and foreign markets.
They are now widely exporting to 200 countries.

Send your inquiry

Choose a different language
English
bahasa Indonesia
Suomi
فارسی
Ελληνικά
dansk
русский
Português
français
italiano
Español
العربية
Deutsch
Zulu
Pilipino
Nederlands
Bahasa Melayu
svenska
Current language:English