Izembatho Zensimbi Eyisivikelo Ezivikelayo Nezivikela Amagundane

Isixhumi se-US Conec MTP® esine-Optimal 0.15dB Type. IL

I-Fiber Engazweli Egobile kanye ne-20/10D (Enamandla/Engaguquki) Min. Bend Radius

Ijakethi engadonsi ngamandla amakhulu okunamathela angu-400N

Isilinganiso Somlilo se-OFNP (Plenum), Esinobungani Nemvelo Futhi Esihlala Isikhathi Eside

Kulungele ukuxhumeka kwangaphakathi okungu-40G/100G okuhlanganisa ama-Data Center Racks, ama-Racks aphakanyisiwe kanye nama-Runs phakathi kwama-Floors

Ihambisana ne-IEC 61754-7, ANSI/TIA-604-5 kanye ne-ANSI/TIA-568.3-D


Imininingwane

Isixhumi A I-US Conec MTP® Elite Female (Ayiphiniwe) Isixhumi B I-US Conec MTP® Elite Female (Ayiphiniwe)
Imodi ye-Fiber I-OS2 9/125μm Ubude begagasi 1310/1550nm
Inani Lefayibha Ama-Fiber angu-12 Ibanga le-Fiber G.657.A1
Uhlobo lwesiPolish I-APC kuya ku-APC Irediyasi Encane Yokugoba 10mm
Ukulahlekelwa Kokufakwa ≤0.35dB (Uhlobo lwe-0.15dB) Ukulahlekelwa Ukubuya
≥60dB
Ukuncipha kwe-1310nm ≤0.35dB/km Ukuncipha kwe-Attention ku-1550nm ≤0.21dB/km

Ububanzi Bekhebula Ngaphandle (OD)

6.0mm Ijakethi Yekhebula I-Plenum (OFNP)
Isakhiwo Sezintambo Zefayibha Ishubhu Elilodwa Elihlomile, Lensimbi Engagqwali Amandla Okudonsa 200/400N (Isikhathi Eside/Esifushane)
Izinga Lokushisa Lokusebenza -10 kuya ku-60°C (14 kuya ku-140℉) Izinga Lokushisa Lesitoreji -10 kuya ku-70°C (14 kuya ku-158℉)


Izixazululo Zokuxhumana

Izici

Ishubhu Lensimbi Eqinile Livikela Ukuxhumeka Kwenethiwekhi Kakhulu

Ishubhu lensimbi engagqwali linganikeza isivikelo esihle ekuphukeni kwefayibha ye-optical futhi lisetshenziswe endaweni enowoyela, igesi kanye nomswakama omncane, okuqinisekisa ukusebenza kwenethiwekhi.

Umsebenzi Osezingeni Eliphezulu Uqinisekisa Ukudluliselwa Okuzinzile

Izixhumi ze-MTP® ziyifomethi yesitayela se-MPO eqinisekisiwe nethembekile enikeza ukusebenza kwe-multi-fiber kanye nokusebenza kwemishini okusezingeni eliphezulu.

I-G.657.A1 Iqinisekisa Ukusebenza Okuphezulu

Ukugoba okuhle kakhulu nokumelana nokucindezelwa kwenza kube ukukhetha okuhle kakhulu kokufaka izintambo ezixinene kakhulu.

Izintambo Ezinobuningi Obuningi Ezindaweni Ezihlukahlukene

Nciphisa imfucuza, thuthukisa ukuphathwa kwekhebula, usheshise ukuthunyelwa, futhi uthuthukise ukuguquguquka nokuphathwa ukuze kuncishiswe izindleko zokufaka.

Hlangana Nezidingo Ezihlukahlukene Zokufakwa Kwangaphakathi

Izintambo ze-patch ezihlomile ezenziwe ngezinto ze-OFNP zizenza zifaneleke ukusetshenziswa okuhlukahlukene kwezintambo ezivundlile.

Ukwakhiwa Kwe-Spine-Leaf Kufinyelela Isilinganiso Senethiwekhi Esikhulu

Vimbela ukuvinjelwa kwenethiwekhi, nciphisa ukubambezeleka kwenethiwekhi, futhi wandise umkhawulokudonsa kanye nokukhula ukuze kwandiswe inethiwekhi esikhathini esizayo.


Imibuzo Evame Ukubuzwa

Umbuzo 1: Iyini i-MTP®-12 armored jumper futhi uyini umehluko phakathi kwe-MTP ne-MPO?

A: I-MTP® inguqulo ye-US Conec esebenza kahle kakhulu yomndeni wesixhumi se-MPO (multi-fiber push-on). I-MTP®-12 jumper iqeda imicu engu-12 kubhangqa elilodwa lesixhumi elihlanganisiwe. Le nguqulo evikelwe ingeza ungqimba lwensimbi oluxhumene ngaphakathi oluzungeze imicu, oluhlinzeka ngokuchoboza okuqinile, ukudonsa kanye nokuvikelwa kwamagundane kunezintambo ze-fiber ezijwayelekile ezindaweni zokufaka eziyingozi.


Umbuzo 2: Kusho ukuthini ukuthi "F kuya ku-F" (owesifazane kuya kowesifazane) futhi kufanele ngi-ode ubulili buni?

A: Izixhumi zesifazane azinazo izikhonkwane zokuqondisa; izixhumi zesilisa zinezikhonkwane zokuqondisa. Le jumper ingeyesifazane neyowesifazane, ubulili obujwayelekile bezintambo ze-trunk/backbone ezihambisana nezixhumi zesilisa ezikhonkiwe kuma-cassette, amamojula noma ama-port emishini. Njalo fanisa ubulili: izixhumi zesifazane zithola izikhonkwane zokuqondisa kusukela ekugcineni kwesilisa.


UMBUZO 3: Iyini i-polarity yohlobo B futhi ihluke kanjani kuhlobo A kanye nohlobo C?

A: Uhlobo B (Indlela B) lusho ukuthi ukuqondiswa kwenkinobho yokuxhumanisa kuphendulwe ekugcineni (ukhiye ukhuphuke uye phansi), kuyilapho izikhundla ze-fiber zibekwe ku-1 kuya ku-1 ngqo — ukukhetha okujwayelekile kwezintambo ze-trunk phakathi kwamaphuzu amabili okuphendla. Uhlobo A luphendulwe ku-key up nge-fiber mapping ehlehlisiwe (1→12), kanti Uhlobo C luphendulwe ngama-fiber pairs ekugcineni. Qinisekisa i-polarity ngomklamo wesistimu yakho ngaphambi koku-oda.


Umbuzo 4: Kungani kusetshenziswa i-APC polish kule jumper yemodi eyodwa?

A: I-APC isebenzisa ubuso bokuphela obune-engile engu-8° okunciphisa kakhulu ukubonakaliswa kwangemuva (ukulahlekelwa okuvamile kokubuya ≥60 dB). Ukubonakaliswa okuphansi kubalulekile ezixhumanisweni ze-OS2 zemodi eyodwa, ama-optics ahambisanayo asheshayo kanye nezinhlelo ze-PON/CATV. I-UPC (i-flat polish) isetshenziselwa izixhumanisi ezijwayelekile zemodi eyodwa noma ezivamile; uhlobo lwe-polish kumele lufane nama-adapter akho nama-transceivers.


Umbuzo 5: Kusho ukuthini ukukala kwe-OFNP plenum futhi le ntambo ingafakwa kuphi?

A: I-OFNP (i-Optical Fiber Cable, i-Plenum) iyisilinganiso esiphezulu kakhulu sokusebenza komlilo ngaphakathi ngokwe-NEC Article 770 kanye ne-UL 910 (ukuhlolwa komhubhe we-Steiner). Ivunyelwe ezindaweni zokuphatha umoya ezifana nophahla olungaphezulu olulengisiwe kanye naphansi aphakeme, futhi iyindlela evumelana nezikhuphuli, amakamelo okuxhumana kanye nezintambo zesakhiwo ezijwayelekile.


Q6: Yiziphi izici zokukhanya zale jumper?

A: Ukulahlekelwa okuphezulu kokufakwa kungu-≤0.35 dB ngepheya ngalinye elihlanganisiwe (ukusebenza okuvamile kuphansi), kanye nokulahlekelwa okuvamile kokubuya kwe-APC okungu-≥60 dB. I-jumper ngayinye ihlolwe ngokuphelele efektri futhi ithunyelwa nerekhodi lokuhlola, ngokuvumelana ne-TIA/EIA-568.3 kanye ne-IEC 61754-7.


Umbuzo 7: Ingabe le jumper RoHS iyahambisana nemithetho futhi ihlangabezana naziphi izindinganiso?

A: Yebo, le khebula iyahambisana ne-RoHS. Iphinde ihlangabezane nezindinganiso zekhebula ze-TIA/EIA-568.3, izidingo ze-interface ye-connector ye-IEC 61754-7 MPO kanye nezilinganiso ze-NEC Article 770 zomlilo (i-OFNP plenum).


Umbuzo 8: Kungani ukhethe ikhebula le-trunk le-MTP elihlomile lezikhungo zedatha kanye namanethiwekhi anabantu abaningi?

A: Isiqu esisodwa se-MTP esine-fiber engu-12 esivikelwe sithatha indawo yezintambo eziningi ezijwayelekile zokubopha ngenkathi sivikela yonke imicu ekuchotshozweni, ekudonsweni, ekukhubekeni nasekulinyazweni yizimpuku kumathileyi ekhebula, ezindleleni ezingaphansi komhlaba kanye nasemizileni yokulungisa izinto. I-armor yensimbi isusa isidingo somhubhe, isindisa isikhala kanye nezindleko ezifakiwe, futhi igcina izixhumanisi ezixinene kakhulu zithembekile ezindaweni ezinothuli, amafutha noma ezinomswakama.


Umbuzo 9: Ngingazithola yini izinketho zobude obungokwezifiso, i-polarity, ubulili noma i-OEM/ODM?

A: Yebo. Sisekela ubude obungokwezifiso (isb. 0.5m–100m), umbala wejakethi, ukuphrinta ilogo, ukwakheka kwelebula kanye nokupakisha, kanye nokulungiselelwa okunye okufana nowesilisa/wesifazane, i-Type A/B/C polarity kanye ne-MTP-to-LC breakout tails. Sicela wabelane ngemininingwane yakho yekhotheshini elungiselelwe wena.


Q10: Iyini i-MOQ, ukupakisha, isikhathi sokulethwa kanye nokuhlolwa?

A: I-MOQ iyaguquguquka futhi ngokuvamile ingama-pcs ayi-100; i-jumper ngayinye ifakwa esikhwameni ngasinye futhi ithunyelwe ngamabhokisi okuthumela ngaphandle. Izinto zesitoko zithunyelwa zingakapheli izinsuku ezingu-3-7; ama-oda enziwe ngokwezifiso ngokuvamile ahlala izinsuku ezingu-15-20 ngemva kokuqinisekiswa. Yonke imikhiqizo ihlolwa ngokuphelele ngaphambi kokuthunyelwa. Xhumana nathi ukuthola amanani amakhulu kanye nemigomo yewaranti.


Imininingwane eyisisekelo
  • Unyaka ususunguliwe
    --
  • Uhlobo lwebhizinisi
    --
  • Izwe / Isifunda
    --
  • Imboni Eyinhloko
    --
  • Imikhiqizo eyinhloko
    --
  • I-Enterprise Lebird
    --
  • Inani labasebenzi
    --
  • Inani lokukhipha lonyaka
    --
  • Thumela Imakethe
    --
  • Amakhasimende Ahlanganisiwe
    --

Kunconyiwe

Thumela uphenyo lwakho

XHUMANA NATHI

Thatha ithuba lolwazi lwethu nolwazi olungenakuqhathaniswa, sikunikeza isevisi engcono kakhulu yokwenza ngokwezifiso.

SITHUMELE UMLAYEZO

Into yokuqala esiyenzayo ukuhlangana namakhasimende ethu futhi sixoxe ngezinjongo zawo kuphrojekthi yesikhathi esizayo.
Kulo mhlangano, zizwe ukhululekile ukuveza imibono yakho futhi ubuze imibuzo eminingi.

KUNCONYWA

Wonke akhiqizwa ngokuvumelana nezindinganiso zamazwe ngamazwe eziqinile. Imikhiqizo yethu ithole umusa kuzo zombili izimakethe zasekhaya nezangaphandle.
Manje sebethumela kakhulu emazweni angama-200.

Thumela uphenyo lwakho

Khetha ulimi oluhlukile
English
bahasa Indonesia
Suomi
فارسی
Ελληνικά
dansk
русский
Português
français
italiano
Español
العربية
Deutsch
Zulu
Pilipino
Nederlands
Bahasa Melayu
svenska
Ulimi lwamanje:Zulu