Ikhebula le-armored fiber patch eline-armored metal armor lingamelana nomonakalo womshini ovela ekuchotshozweni, ekukhubekeni, ekusikeni nasekudonsweni ezindaweni eziyingozi kakhulu. Lingavikela imicu futhi livimbele ukungasebenzi kwenethiwekhi. Ukwakhiwa kwe-armor kuqeda isidingo se-conduit ukuze kuhlinzekwe indlela encane, engacindezeleki yokuguquguquka komklamo kanye nezindleko eziphansi ezifakiwe.
Okuvelele Komkhiqizo
Izembatho Zensimbi Eyisivikelo Eziyindilinga Zinikeza Ukuvikelwa Okwengeziwe Kokuchoboza, Ukugoba, Ukudonsa, kanye Nokuvikela Amagundane
Susa Isidingo Semifudlana Yokuthuthukisa Ukuguquguquka Komklamo kanye Nezindleko Eziphansi Ezifakiwe
Ijakethi engadonsi ngamandla amakhulu okunamathela angu-225N
I-G.657.A1 I-Fiber Engazweli Ukugoba kanye ne-10/5D (Enamandla/Engaguquki) Min. Bend Radius
Izixhumi ze-Zirconia Ferrule eziqondile ziqinisekisa ukulahlekelwa okuphansi
Isetshenziswa Emgodini Wokwakha Ngaphakathi, Ukufakwa Okuvundlile, kanye Nezicelo Ezidinga Ukuqina Okungeziwe
Imininingwane
| Uhlobo Lokuxhuma | Ukusuka ku-LC kuya ku-LC | Uhlobo lwesiPolish | I-UPC kuya ku-UPC |
| Imodi ye-Fiber | I-OS2 9/125μm | Inani Lefayibha | I-Simplex |
| Ibanga le-Fiber | G.657.A1 (Ihambisana ne-G.652.D) | Irediyasi Egobile Encane (Ikhebula Le-Fiber) | 10/5D (Enamandla/Engaguquki) |
| Ububanzi Bekhebula Ngaphandle (OD) | 3.0mm | Isilinganiso Samalangabi | I-Riser (i-OFCR-Optical Fiber Conductive Riser) |
| Uhlobo Lokwakha | Ishubhu Elilodwa Elihlomile, Lensimbi Engagqwali | Amandla Okudonsa | 120/225N (Isikhathi Eside/Esifushane) |
| ≤0.3dB | Ukulahlekelwa Ukubuya | Ukulahlekelwa Ukubuya | ≥50dB |
| Izinga Lokushisa Lokusebenza | -20 kuya ku-70°C (-4 kuya ku-158°F) | Izinga Lokushisa Lesitoreji | -40 kuya ku-70°C (-40 kuya ku-158°F) |
Izixazululo Zokuxhumana

Izici
Ishubhu Lensimbi Eqinile Livikela Ukuxhumeka Kwenethiwekhi Kakhulu
Ishubhu lensimbi engagqwali linganikeza isivikelo esihle ekuphukeni kwefayibha yokukhanya kanye nomonakalo womshini ukudala inethiwekhi yefayibha yokukhanya ethembekile nesebenza kahle kakhulu.

Ikhebula Elisezingeni Lomthwali Liqinisekisa Ikhwalithi Yokudlulisa
Ukuhlanganiswa kwekhebula okuphezulu kuqinisekisa ukudluliswa kwesignali okuzinzile kanye nokuthembeka kwesikhathi eside, kunciphisa amazinga okuhluleka.

Hlangana Nezidingo Ezihlukahlukene Zokufakwa Kwangaphakathi
Ukuqina okungavamile kwezintambo ezivikelwe kungasetshenziswa ukuvikela imicu nokuthuthukisa ukuthembeka kwenethiwekhi yezinhlelo zokusebenza ezahlukahlukene.
|
| |
| Izintambo ze-OS2 ezihlomile | Amakhebula ajwayelekile e-OS2 | |
| Inani Lefayibha | I-Simplex / 1 Fiber | I-Simplex / 1 Fiber |
| Ibanga le-Fiber | G.657.A1 | G.657.A1 |
| Ijakethi | I-Riser (i-OFCR-Optical Fiber Conductive Riser) | I-Riser (OFNR) |
| Ububanzi bekhebula | 3.0mm | 2.0mm |
| Ukulahlekelwa Kokufakwa | ≤0.3dB | ≤0.3dB |
| Irediyasi Egobile Encane (Ikhebula Le-Fiber) | 10/5D (Enamandla/Engaguquki) | 10/5D (Enamandla/Engaguquki) |
| Izinga Lokushisa Lokusebenza | -25 kuya ku-70°C (-13 kuya ku-158℉) | -20 kuya ku-70°C (-4 kuya ku-158℉) |
| Isicelo | Izindawo Eziyingozi Zangaphakathi | Ngaphakathi, Isakhiwo Esijwayelekile |
Imibuzo Evame Ukubuzwa
Umbuzo 1. Iyini ikhebula le-fiber patch elivikelwe?
Ikhebula le-armored fiber patch (elibizwa nangokuthi i-armored fiber jumper noma i-armored patch cord) liyi-fiber optic jumper enesendlalelo se-armored metal armor esakhelwe ngaphakathi - ngokuvamile i-armored steel interlocking armor - esongwe nge-fiber core futhi ivikelwe yijazi langaphandle. Lesi armored metal armor esakhelwe ngaphakathi simelana nomonakalo womshini ovela ekuchotshozweni, ekukhubekeni, ekusikeni, nasekudonseni ezindaweni eziyingozi kakhulu, sivikela imicu futhi sivimbele ukuphuma kwenethiwekhi. Ukwakhiwa kwe-armored kuqeda isidingo se-conduit, kunikeza indlela encane, engacindezeleki yokuguquguquka komklamo okuthuthukisiwe kanye nezindleko eziphansi ezifakiwe.
Umbuzo 2. Yiziphi izici ezibalulekile zale ntambo ye-patch ene-armored ye-KEXINT?
Inani le-fiber: i-fiber eyi-1 (i-simplex)
Isixhumi: I-LC/UPC kuya ku-LC/UPC simplex
Imodi yefayibha: Imodi eyodwa OS2 9/125μm, G.657.A1 (iyahambisana ne-G.652.D)
Isilinganiso sejakethi: I-Riser (OFCR)
Ububanzi bekhebula: 3.0mm
Umbala wejakethi: Oluhlaza okwesibhakabhaka
Ukulahleka okuvamile kokufakwa: ≤0.2dB; ukulahleka kokubuyiselwa: ≥50dB (UPC)
Umbuzo 3. Isivikelo sensimbi sivikelani?
Isivikelo esixhumene nensimbi engagqwali sivikela ifayibha ekuchotshozweni, ekukhubekeni, ekusikeni nasekudonseni, futhi sinikeza ukumelana okuqinile nokulunywa yizimpuku. Senzelwe izindawo eziyingozi kakhulu lapho izintambo ezijwayelekile zokubopha zingase zingasebenzi khona - ukuvikela ifayibha nokuvimbela ukunqamuka kwenethiwekhi.
Umbuzo 4. Uyini umehluko phakathi kwezintambo ze-fiber patch ezivikelwe kanye nezingezona ezivikelwe?
Intambo ye-fiber patch ejwayelekile (engahlomile) inejakethi ye-PVC/LSZH kuphela, eguquguqukayo kodwa esengozini yokuchotshozwa, ukusika, kanye nokulimala kwegundane. Ikhebula le-fiber patch elihlomile lengeza ungqimba lwe-armor yensimbi phakathi kwe-fiber nejakethi yangaphandle, enikeza ukumelana nokuchotshozwa kanye nokuvikelwa kwegundane ngaphandle kokudinga i-conduit. Ukushintshana kukhulu kancane ububanzi (3.0mm vs 2.0mm) futhi kuncishisiwe ukuguquguquka uma kuqhathaniswa nama-jumper angenazo izikhali.
Umbuzo 5. Isho ukuthini imodi eyodwa ye-OS2? I-OS2 iyigama le-ISO/IEC 11801 le-fiber optical yemodi eyodwa (9/125μm) elungiselelwe izixhumanisi zangaphandle/ezifinyelela kude. Ama-fiber emodi eyodwa ye-OS2 asekela i-10G, 40G, 100G nangaphezulu emabangeni amade, okwenza le jumper ye-fiber enezivikelo ifanelekele i-backbones yekhampasi, ukuxhumana kwesikhungo sedatha, kanye namanethiwekhi ezinkampani.
Umbuzo 6. Yiliphi izinga le-fiber elisetshenziswayo, futhi kungani kubalulekile? Le ntambo ye-armored patch isebenzisa i-fiber ye-G.657.A1, ehambisana ngokugcwele ne-G.652.DG657.A1 iyi-fiber yemodi eyodwa engazweli ukugoba ebekezelela i-radii egobile eqinile ngaphandle kokulahlekelwa okukhulu kwesiginali - kubalulekile lapho kudluliswa izintambo ezivikelwe ezikhaleni ezivalekile, amakhona, kanye namathreyi ekhebula.
Umbuzo 7. Kusho ukuthini ukuthi i-LC/UPC simplex kuya ku-LC/UPC simplex? Kusho ukuthi zombili iziphetho zentambo yesichibi ziqedwa ngezixhumi ze-LC ezisebenzisa i-UPC (Ultra Physical Contact) polish, futhi ikhebula liqukethe i-fiber eyodwa (simplex). I-LC iyisixhumi esincane esisetshenziswa kakhulu esikhungweni sedatha esinobuningi obukhulu kanye nezintambo zebhizinisi; i-UPC polish inikeza ukulahlekelwa okuphansi kokufakwa kanye nokulahlekelwa okuphezulu kokubuya (≥50dB) kwezinhlelo zokusebenza zemodi eyodwa.
Umbuzo 8. Ingabe ikhebula elihlomile elingu-3.0mm lisaguquguquka? Yebo. Ububanzi obungu-3.0mm buhlanganisa isivikelo sensimbi nejazi langaphandle, kodwa isivikelo esixhumene senzelwe ukugoba ngenkathi simelana nokuchotshozwa. Uma uqhathanisa, izintambo ezingenalutho ezihlomile zivame ukuba ngu-2.0mm, kuyilapho izinhlobo ezihlomile zivame ukuba ngu-3.0mm — ukwanda kosayizi okulinganiselwe okusiza ekuvikeleni okwenziwa ngomshini. Ama-jumper e-fiber ahlomile aguquguqukayo asetshenziswa kabanzi ezindaweni ezilinganiselwe.
Umbuzo 9. Kusho ukuthini isilinganiso se-OFCR / Riser?
I-OFCR imele i-Optical Fiber Conductive Riser, isilinganiso sokuphepha komlilo se-UL samakhebula e-optical fiber avunyelwe ukugijima okuqondile phakathi kwezitezi (izikhala zokuphakama) ezakhiweni zezentengiselwano. I-fibre enezivikelo ezilinganiselwe i-Riser iyimfuneko ejwayelekile kumaphrojekthi wokwakha aseNyakatho Melika; AYIFANELEKI ezindaweni zokuphatha umoya ze-plenum — kulabo, khetha ikhebula elilinganiselwe le-OFNP (plenum).
Umbuzo 10. Ngingayisebenzisa yini le ntambo ye-armored enesilinganiso sokukhuphuka ngaphandle komsele?
Yebo — lokho kungenye yezinzuzo zayo ezibalulekile. Isembozo sensimbi esakhelwe ngaphakathi sinikeza isivikelo semishini esinganikezwa yi-conduit ngaphandle kwalokho, sisusa isidingo sokuba i-conduit ilethe indlela encane, engacindezeleki. Lokhu kuthuthukisa ukuguquguquka komklamo futhi kunciphisa izindleko ezifakiwe, ikakhulukazi ekufakweni kabusha nasekufakweni kwezimboni.
Umbuzo 11. Le ntambo ye-fiber patch evikelwe ivame ukusetshenziswa kuphi?
Izinhlelo zokusebenza ezijwayelekile zifaka: ukufakwa kwezintambo zesikhungo sedatha kanye nokufakwa kwezintambo ezibanzi, amanethiwekhi ebhizinisi kanye nekhampasi, ukuzenzekela kwezimboni kanye nezitezi zasefektri, ukufakwa kwe-FTTH/FTTA, ukuguqulwa kwangaphandle kuya endlini, izinhlelo zokuphepha/zokuqapha, kanye nanoma iyiphi indawo enzima lapho kudingeka khona ukuvikelwa kokuchotshozwa, ukukhuhlana, noma amagundane.
Umbuzo 12. Ingabe le jumper ene-fiber jumper imelana namagundane?
Yebo. Isivikelo esixhumene nensimbi engagqwali siyisithiyo esisebenzayo ngokumelene nokulunywa yizimpuku, imbangela evamile yokwehluleka kwefayibha ezindaweni zokugcina impahla, ezindlini ezingaphansi komhlaba, emihubheni, nasezindaweni ezingaphandle eziseduze. Lokhu kuyenza ibe yi-fiber jumper efanelekile engangenwa yizimpuku ezindaweni zezimboni.
Umbuzo 13. Yiziphi izincazelo zokusebenza kwe-optical?
Ukusebenza okuvamile kokukhanya: ukulahlekelwa kokufakwa ≤0.2dB, ukulahlekelwa kokubuyiselwa ≥50dB (i-UPC polish). Zonke izintambo zihlolwe ngokuphelele efektri ngaphambi kokuthunyelwa. Amanani aqondile abhalwe kudatha ye-KEXINT futhi angenziwa ngezifiso ngokwezidingo zephrojekthi.
Umbuzo 14. Yiziphi izincazelo zemishini — ukumelana nomthwalo ocindezelekile kanye nokuchotshozwa?
Isendlalelo sezivikelo sikhulisa kakhulu amandla okudonsa kanye nokumelana nokuchoboza uma kuqhathaniswa nama-jumper ajwayelekile (amandla okudonsa ajwayelekile >10kg ezintambo zokunamathisela; izinhlobo ezivikelwe zimelana namandla okuchoboza aphezulu kakhulu). Amanani athile ancike ekwakhiweni futhi aqinisekiswa ekuhlolweni kwefektri - xhumana ne-KEXINT ukuthola ishidi eliphelele lemininingwane yemishini.
Umbuzo 15. Lingakanani izinga lokushisa lokusebenza?
Izinga lokushisa lokusebenza elijwayelekile lisukela ku-40°C kuya ku-+85°C, lifanele kokubili izindawo zangaphakathi nezangaphandle eziseduze. Ukuhlolwa kokuqina kwezinga lokushisa kukhombisa ukwehluka okungu-≤0.2dB kulo lonke ububanzi.
Umbuzo 16. Ngingakwazi yini ukwenza ngokwezifiso ubude, izixhumi, noma uhlobo lwe-polish?
Yebo. I-KEXINT inikeza ukwenza ngokwezifiso okugcwele: noma yibuphi ubude kusukela ku-0.5m kuya kubude be-spool ngokwezifiso; izinhlobo zezixhumi i-LC, i-SC, i-FC, i-ST; izinhlobo ze-polish i-UPC noma i-APC; i-simplex noma i-duplex; imibala yejakethi; kanye nokulebula ngokwezifiso. Umkhiqizo we-OEM/ODM owenziwe ngokwezifiso uyatholakala kuma-oda amaningi.
Umbuzo 17. Iyini i-MOQ nesikhathi sokukhokha?
I-MOQ iqala kusukela kucezu olulodwa kumasampula (intengo yesampula iyatholakala uma iceliwe). I-MOQ ejwayelekile yokukhiqiza izingcezu eziyi-100; isikhathi sokuhola ngokuvamile siyizinsuku eziyi-7-15 kuye ngobuningi kanye nokwenza ngokwezifiso. Amandla okukhiqiza e-KEXINT asekela izingcezu ezifika ku-10,000 ngosuku.
Umbuzo 18. Yiziphi izitifiketi ezinazo ikhebula le-KEXINT armored fiber patch? Imikhiqizo ye-KEXINT yenziwa ngaphansi kokuphathwa kwekhwalithi ye-ISO 9001:2015 futhi ihambisana nezidingo ze-RoHS kanye ne-CE. Amajakethi anesilinganiso se-UL (i-OFCR riser) asetshenziswa kulo mkhiqizo. Izitifiketi ziyatholakala uma ziceliwe ukuze uthole imibhalo yephrojekthi yakho.
Umbuzo 19. Ngingayifaka kanjani i-oda eliningi noma ngicele ikhotheshini?
Thumela umbuzo wakho ngefomu lokuxhumana lewebhusayithi, i-imeyili (info@kexint.com), noma i-WhatsApp. Ukuze ucaphune ngokunembile, sicela unikeze: inani lefayibha, uhlobo lwesixhumi kanye nokupholisha (isb., i-LC/UPC), imodi yefayibha (OS2/OM3/OM4), ububanzi bekhebula, ubude, isilinganiso sejakethi (i-riser/plenum), kanye nobuningi. Ithimba lethu lokuthengisa liphendula zingakapheli amahora angama-24.
Umbuzo 20. Ikhwalithi ilawulwa kanjani, futhi iyiphi iwaranti oyinikezayo?
Ikhebula ngalinye le-fiber patch elivikelwe lihlolwa ngo-100%, ukuhlolwa kokulahlekelwa kokufakwa/ukubuyiselwa, kanye nokuhlolwa komkhiqizo oqediwe ngaphambi kokuthunyelwa. I-KEXINT inikeza iwaranti yeminyaka emi-3 kumakhebula e-fiber patch. Singumkhiqizi wekhebula le-fiber optic elivikelwe yi-ISO 9001 elinentengo eqondile evela efektri.
XHUMANA NATHI
Thatha ithuba lolwazi lwethu nolwazi olungenakuqhathaniswa, sikunikeza isevisi engcono kakhulu yokwenza ngokwezifiso.
SITHUMELE UMLAYEZO
I-HOTLINE
+8613509645699
I-EMAIL
KUNCONYWA
Wonke akhiqizwa ngokuvumelana nezindinganiso zamazwe ngamazwe eziqinile. Imikhiqizo yethu ithole umusa kuzo zombili izimakethe zasekhaya nezangaphandle.
Manje sebethumela kakhulu emazweni angama-200.